翻訳と辞書
Words near each other
・ Emerald Necklace
・ Emerald network
・ Emerald Nunatak
・ Emerald O'Hanrahan
・ Emerald of the East
・ Emerald on the Roof
・ Emerald Pacific Airlines
・ Emerald Palace
・ Emerald Park, Saskatchewan
・ Emerald Peak
・ Emerald Plaza (San Diego)
・ Emerald Point N.A.S.
・ Emerald poison frog
・ Emerald Pool
・ Emerald Princess
Emerald Program
・ Emerald railway station
・ Emerald railway station, Queensland
・ Emerald railway station, Victoria
・ Emerald Records
・ Emerald Records (1966)
・ Emerald Records (2000s)
・ Emerald Ridge High School
・ Emerald River
・ Emerald rockcod
・ Emerald Rose
・ Emerald shiner
・ Emerald skink
・ Emerald Society
・ Emerald Software


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Emerald Program : ウィキペディア英語版
Emerald Program
The SNIA Emerald Program Power Efficiency Measurement Specification,〔SNIA Emerald Power Efficiency Measurement Specification Approved specification for measuring power efficiency of storage systems http://www.snia.org/tech_activities/standards/curr_standards/emerald〕 is a storage specification developed and maintained by the Storage Networking Industry Association (SNIA) and cross-referenced by the Environmental Protection Agency’s EnergyStar program.〔EPA ENERGY STAR Data Center Storage program http://www.energystar.gov/products/spec/data_center_storage_specification_version_1_0_pd〕 The specification consists of a storage types taxonomy, system under test workload and energy measurement method, measured metrics for active and idle operational states, and presence tests for capacity optimization technologies. The measured metric data is generated through the use of well-defined standard testing and data reduction procedures prescribed in the SNIA Emerald Specification.〔SNIA Emerald Power Efficiency Measurement Specification Approved specification for measuring power efficiency of storage systems http://www.snia.org/tech_activities/standards/curr_standards/emerald〕 This data quantifies storage system power efficiency for typical types of enterprise datacenter workloads and helps IT professionals make storage platform selections as part of an overall Green IT and sustainability objective.
SNIA's ongoing collaboration with the EPA has helped to shape the Energy Star Data Center Storage (DCS) Specification.〔
*EPA ENERGY STAR Data Center Storage: published product power efficiency data http://www.energystar.gov/productfinder/product/certified-data-center-storage〕 The EPA DCS specification cross-references the SNIA Emerald Specification as the test and measurement methodology.〔http://www.energystar.gov/index.cfm?c=products.pr_crit_data_storage_centers〕〔(The ENERGY STAR storage taxonomy is consistent with the taxonomy developed by the Storage Networking Industry Association Green Storage Initiative as defined in "SNIA Emerald Power Efficiency Measurement Specification" Version 2.0.0 rev 1, 12 December, 2012 )〕
== References ==


抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Emerald Program」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.